High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine

Product Details
Customization: Available
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Still deciding? Get samples of US$ 11000/Piece
Request Sample
Manufacturer/Factory, Trading Company, Other, Group Corporation

360° Virtual Tour

Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
15000000 RMB
Plant Area
>2000 square meters
  • High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
  • High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
  • High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
  • High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
  • High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
  • High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
Find Similar Products
  • Overview
  • Product Description
  • Clinical Images
  • customers feedback
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
RD-850X
Product Name
Floor-Mounted Digital X-ray Equipment
Model No.
Rd-850X
Detector Size
17"*17"
Pixel
3072*3072
Output Power
50kw
Item
X Ray Machine
Exposure Kv
40kv-125kv
Tube Current Range
10mA ~ 630mA
Power Supply
100-240V, 50Hz/60Hz
Nominal Tube Voltage
125kv
Inverter Frequency
25kHz
Transport Package
Standard Export Package
Specification
3.5 M3
Trademark
Dawei
Origin
China
HS Code
9022140090
Production Capacity
50000

Product Description

high-frequency DR 50KW fixed Digital radiography X-ray Machine

Product Description
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine


 

No. Component Performance parameter
1 Medical diagnostic X-ray high-frequency high-voltage generator Output Power: 50kW
Input Voltage: 220VAC,±10%,50Hz
Inverter Frequency: 25kHz,±10%
kV range: 40 kV~150kV
mA range: 10 mA~630 mA
ms range: 1ms~6300 ms
mAs range: 0.1mAs~150mAs
Tech mode: kV-mA(AEC);kV-mAs;kV-mA-ms
APR: 2000
AEC(Optional):  AEC Ionization chamber power supply:+/-15V
Minimum exposure time:5ms
Auxiliary power supply: +24V DC 2A;24V AC 8A
Communication Interface: RS-232
2 X-ray Tube Assembly X-ray Tube Voltage Range: 40kV~125kV
Nominal Focal Spot Value:
0.6mm(Small Focus)/1.2mm(Large Focus)
Nominal Anode Input Power:
20kW(Small Focus)/40kW(Large Focus)
Anode Heat Content: 300KHu
3 Flat Panel Detector Image Sensor: a-Si (Amorphous Silicon) TFT
Scintillator: CsI:Tl
Effective Array: 3072 ×3072
Pixel Size: 139 um
Effective Area (H x V): 427mm×427mm
Preview Time: 3s
Imaging Time: 5s
Spatial Resolution: 3.6 lp/mm
AD Conversion: 16 bit
Data Interface: Gigabit Ethernet
Trigger Mode: AED(optional)/Software/Prep
Dimension (L × W × H): 460mm×460mm×15mm
Weight: 4kg
Power Consumption: 20W
4 Collimator Control Mode: Manual control
Maximum Radiation: 150kV
Inherent Filtration Al. Equivalent: 1mm AL
Rectangular X-ray Field Selection 
Set Focus Distance, SID=100cm: Min 2cm×2cm;Max 43cm×43cm
X-Ray Field Deviation: ≤1% of SID
Light Field Indicator @ SID=100cm: ≥180lux
Light Field Indicator Precision: ≤1% of SID
Light source ON time: 30s
Maximum Radiation Leakage EN 60601-1-3: <0.5mGyh
Power Supply: 24V AC/DC,Max.4A
Dimension: 206mm×230mm×143mm
Weight: 7.0kg±0.5kg
8 Dawei DR image acquisition and processing software This software is comprised of following modules which provides a workflow of patient study:
Patient Management: including patient registration, work list, study management.
Study operation: including body part selection, study items selection, image acquiring.
Image preview: including display, layout and processing of image. Also tool options for advanced operation.
Configuration: including configuration of system, study and user management. Especially the configuration for worklist and storage.  
The image processing tools are as follows:
Flip vertical, flip horizontal, rotate -90°, rotate 90°, free rotate, window/level change, auto WW/WL, ROI window/level, invert color, image stitching, reject image, zoom in/out, image advanced process, reset the image, invalid image, measure the angle, distance measure, point gray value of the image, ROI magnifier, magnifier, image hint, CTR(cardio-thoracic ratio) tool, arrow tool, copy tool, paste tool, email tool, cobb angle, monitor calibration tool, save as tool, compare tool and inverse compare tool.
Other tools: mark left, mark right, mark anterior, text edit, clip tool, clip options tool, ellipse clip tool and delete tool.

 

Clinical Images

 

High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine

 

Doctor recommendation

 

High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine

 

customers feedback

 

High Frequency Dr System 50kw Fixed Digital Radiography X-ray MachineHigh Frequency Dr System 50kw Fixed Digital Radiography X-ray MachineHigh Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine
  1.  
Certifications

High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine

 

Company Profile

 


High Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine

High Frequency Dr System 50kw Fixed Digital Radiography X-ray MachineHigh Frequency Dr System 50kw Fixed Digital Radiography X-ray Machine

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier