1: | Summary of main specifications and system of cart type color Doppler ultrasound | |
1.1 | Trolley type all digital color Doppler ultrasonic mainframe | |
1.2 | Ultrasonic host operating system: Windows operating system | |
1.3 | Applications: Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal |
|
1.4 | Probes: Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume probe |
|
1.5 | Applications and report: Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc. |
|
☆1.6 | carotid artery intima measurement thickness(IMT) | |
☆1.7 | Automatic spectral envelope measurement | |
1.8 | Full digital transmission and reception of beam synthesizer | |
1.9 | Color Doppler imaging(C) | |
1.10 | Pulse Doppler Imaging(PW) | |
☆1.12 | Coherent Contrast imaging(CCI) | |
1.12 | Continuous wave Doppler imaging(CW) | |
☆1.13 | B/C/D Real-time three synchronous imaging | |
☆1.14 | Power Doppler imaging(PDI) | |
☆1.15 | Direct power Doppler imaging(DPDI) | |
1.16 | M mode imaging | |
☆1.17 | Anatomic M mode imaging | |
☆1.18 | Color Doppler M mode imaging | |
☆1.19 | Elastography | |
☆1.20 | Tissue Doppler imaging(TDI) | |
☆1.21 | Strain rate imaging (SRI) | |
1.22 | Tissue harmonic imaging(THI) | |
1.23 | Fusion harmonic imaging(FHI) | |
1.24 | Speckle Reduce imaging(SRI) | |
☆1.25 | Panoramic imaging | |
☆1.26 | Deflection imaging | |
☆1.27 | Trapezoidal imaging | |
1.28 | Adaptive velocity optimization | |
☆1.29 | Free hand 3D | |
1.30 | Real time 3D imaging(3D/4D) | |
1.31 | DICOM3.0 | |
1.32 | Monitor:≥21.5 inch,high definition ultrasonic display | |
1.33 | ≥13.3 inch touch screen | |
1.34 | Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted. | |
1.35 | The system has the function of on-the-spot upgrade | |
1.36 | Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation. | |
1.37 | Probe interface: 4 | |
1.38 | System languages: Chinese/English/ Spanish/ Portuguese/ French/ Russian/ Arabic/ Vietnamese/ Indonesian/ German |
|
1.39 | Depth:≥360mm; | |
1.40 | Extended imaging |
2D imaging mode | |
Gain:0-100,Step 2 adjustable | |
TGC:8 segment adjustable | |
Maximum focus point:≥7, which can be moved throughout the whole process. | |
Speckle reduction:0-5,5 level | |
Space Synthesis:0-2,2 level(Liner probe: 3 level, cardiac probe:0) | |
Dynamic:30-180,35 level,step 5 adjustable | |
Line density:low,middle,high,3 level | |
Frame correlation:0-4,4 level | |
Noise reduction:0-5,5 level | |
Edge Enhancement:0-5,5 level | |
Sound power:2-10, 9 level | |
Grey scale:0-67, 67 level | |
False color:0-67,67 level | |
Image style:Soft-Comparison,2 level | |
The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted | |
Color Doppler imaging mode | |
Blood gain:0-100,Step 2 | |
Parameter display:Velocity,Variance | |
B-Restrain(B/W restrain):0-7, 7 level | |
Speed Through:0-8, 8 levels | |
Sampling number:6-24, 7 level | |
Blood flow preferred:0-8, 8 level | |
Filtering:1-6, 6 level | |
Sound power:2-6, 4 level | |
Noise reduction:0-4, 4 level | |
Smooth treatment:0-4, 4 level | |
Frame correlation:0-6, 6 level | |
Chromatography(Blood flow graph):0-37, 37 level | |
Line density:Low-Middle-High, 3 level | |
Frequency:4 level adjustable | |
Velocity:Minimum 0.4K,Maximum 40.5K Convex probe:0.4K-4.3K-38.5K Linear probe:0.4K-14.7K-39.0K Trans-vaginal probe:0.4K-7.8K-39.7K Volume probe:0.4K-4.2K-34.8K Micro-convex probe:0.4K-10.3K-40.5K cardiac probe:0.4K-7.8K-39.7K |
|
PS:The frequency of the probe changes and the frequency value changes | |
PS:Frame rate changes with speed | |
Pulse wave Doppler(PW) | |
Gain:0-100,Step 2 | |
Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close | |
Sample volume:0.5mm~30mm | |
Blood angel:-75-75 degree,Step 5 | |
False color:0-67, 67 level | |
Dynamic range:20-40, 4 level | |
Filter:0-9, 9 level | |
Smooth treatment:1-4, 4 level | |
Sound power:2-5, 4 level | |
Volume:0-100, 10 level,Step 10 | |
Audio filtering:0-4, 4 level | |
Base line:-1.0~1.0, | |
Grey map:0-67, 67 level | |
Scan velocity:100-500, 6 level | |
PRF:Minimum 0.5K,Maximum 87.5K Convex probe:0.5K-4.3K-63.3K Linear probe:0.5K-14.5K-78.4K Trans-vaginal probe:0.5K-8.1K-78.4K Volume probe:0.5K-4.2K-53.8K Micro-convex probe:0.5K-10.3K-81.1K cardiac probe:0.5K-4.3K-87.5K |
|
Frequency:4 level | |
PS:The frequency of the probe changes and the PRF value changes | |
PS:The frequency of the probe changes and the frequency value changes |