carotid artery intima measurement thickness(IMT)
|
Automatic spectral envelope measurement
|
Full digital transmission and reception of beam synthesizer
|
Color Doppler imaging(C)
|
Pulse Doppler Imaging(PW)
|
Coherent Contrast imaging(CCI)
|
Continuous wave Doppler imaging(CW)
|
B/C/D Real-time three synchronous imaging
|
Power Doppler imaging(PDI)
|
Direct power Doppler imaging(DPDI)
|
M mode imaging
|
Anatomic M mode imaging
|
Color Doppler M mode imaging
|
Elastography
|
Tissue Doppler imaging(TDI)
|
Strain rate imaging (SRI)
|
Tissue harmonic imaging(THI)
|
Fusion harmonic imaging(FHI)
|
Speckle Reduce imaging(SRI)
|
Panoramic imaging
|
Deflection imaging
|
Trapezoidal imaging
|
Adaptive velocity optimization
|
Real time 3D imaging(3D/4D)
|
Free hand 3D
|
Color Doppler imaging mode
|
Blood gain:0-100,Step 2
|
Parameter display:Velocity,Variance
|
B-Restrain(B/W restrain):0-7, 7 level
|
Speed Through:0-8, 8 levels
|
Sampling number:6-24, 7 level
|
Blood flow preferred:0-8, 8 level
|
Sound power:2-6, 4 level
|
Noise reduction:0-4, 4 level
|
Smooth treatment:0-4, 4 level
|
Frame correlation:0-6, 6 level
|
Chromatography(Blood flow graph):0-37, 37 level
|
Line density:Low-Middle-High, 3 level
|
Frequency:4 level adjustable
|
Pulse wave Doppler(PW)
|
Gain:0-100,Step 2
|
Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope,
and other modes. The system automatically analyses and displays various data such as PSV, EDV,
RI, PI, S/D, ACC, HR and so on. Can wake up or close
|
Sample volume:0.5mm~30mm
|
Blood angel:-75-75 degree,Step 5
|
False color:0-67, 67 level
|
Dynamic range:20-40, 4 level
|
Filter:0-9, 9 level
|
Smooth treatment:1-4, 4 level
|
Sound power:2-5, 4 level
|
Volume:0-100, 10 level,Step 10
|
Audio filtering:0-4, 4 level
|
Base line:-1.0~1.0
|
Grey map:0-67, 67 level
|
Scan velocity:100-500, 6 level
|
PRF:Minimum 0.5K,Maximum 87.5K
|
Continuous Wave Doppler(CW)
|
Support probe:Cardiac probe
|
Adjustment of B mode parameters is switchable
|
Gain:0-100,Step 2
|
Sampling line position is adjustable
|
PRF:0.9K~36.1K
|
Baseline:-1.0~1.0
|
Blood angel:-75~75 degree
|
Grey map:0-67
|
Scan velocity:100-300
|
False color:0-67
|
Dynamic range:20-40
|
Filtering:0-9,9 level
|